Climate control panel for OEM
| ID 1500
order development
developed on the basis of a design template
for DIN mounting frame slot
customized fully graphic LCD
11 buttons and 2 rotary knobs
Night illumination in amber color
Dimensions (L x W x H): 187 x 58 x 55 mm
|
|  |
 |
Hatch Control
| ID 9411
Control panel for up to 4 roof hatches
Ownership: Exotronic
Compatible with DHC and ELEON control unit
Operating temperatur: -40 ... +85 °C
Fully digital with memory function
Status display of each roof hatch
Night illumination
Dimensions (L x W x H): 87 x 61 x 37 mm
|
|
|  |
 |
|
SC Preheat
| ID 1094
Pre-selection timer for heaters
serial production
7 day pre-selection timer
Illuminated flat membrane keyboard
Power failure bypass 72 hours
12 h / 24 h mode
Protection class IP54 (front)
Operating voltage: 12- and 24 V
Dimensions (L x W x H): 89 x 42 x 41 mm
|
|  |
 |
High-voltage control unit for PTC heater
| ID 1005
order development
Control of 2 PTC heaters with up to 1,200 V
IP 67 in a CNC milled and sealed aluminum housing
internal security concept
CAN- and S-Bus compatible
Dimensions (L x W x H): 190 x 135 x 56 mm
|
|
|  |
 |
|
Control unit for roof hatch ELEON
| ID 1003
order development
Control of 4 motors (always two sequentially)
Operating temperatur: -40 ... +85 °C
Operating voltage: 12- and 24 V (2 versions)
CAN- and S-Bus protocol
extremely compact and powerful assembly
Mounting without screws (clip)
Dimensions (L x W x H): 85 x 56 x 24 mm
|
|  |
 |
Control unit Thermo E
| ID 1071 For heating system
order development
Operating voltage: 24 V
Operating temperatur: -40 ... +85 °C
Integrated flame detection
for price-critical markets
Dimensions (L x W x H): 114 x 101 x 55 mm
|
|
|  |
 |
|
Control unit Thermo E+
| ID 1080 For heating system
order development
diagnostic ability with DTT
Operating voltage: 12- and 24 V (2 versions)
Operating temperatur: -40 ... +85 °C
extremely compact and powerful assembly
integrated circuit for ignition spark generator
Outside IP 67 Schutz (vacuum potting)
integrated flame detection
Dimensions (L x W x H): 112 x 69 x 38 mm
|
|  |
 |
Control unit Thermo S
| ID 1018 For heating system
A control unit, produced by another company for years, had to be converted for our production facility as quickly as possible. In addition to making adjustments to auxiliary devices for our machines, we also had the challenge of redeveloping an end-of-line testing device that was getting on in years. We mastered this conversion process, atypical for us, and have been producing a premium control unit for vehicle heaters at our company since December 2021.
|
|
|  |
 |
|
Control unit Thermo G
| ID 1089 For heating system
order development
diagnostic ability with DTT
Operating voltage: 24 V
Operating temperatur: -40 ... +85 °C
Integrated ionization monitoring
integrated circuit for ignition spark generator
Outside IP 67 Schutz (vacuum potting)
Dimensions (L x W x H): 108 x 100 x 58 mm
|
|  |
 |
Digital Hatch Control (DHC)
| ID 9413 Control unit for roof hatch
Ownership: Exotronic
Compatible with Driver Unit control panel
diagnostic ability with DTT
Operating voltage: 24 V
Operating temperatur: -40 ... +85 °C
Override closing function (AC)
Configurable
Dimensions (L x W x H): 75 x 62 x 20 mm
|
|
|  |
 |
|
Digital Hatch Control 2
| ID 9414
New control unit for roof hatch
Ownership: Exotronic
End position detection via motor current monitoring
Operating voltage: 24 V
100% compatible with the DHC
CAN and S-Bus interface
Dimensions (L x W x H): 75 x 55 x 17 mm
|
|  |
 |
PWM module
| ID 9450
Ownership: Exotronic
Operating voltage: 9 ... 32 V
Operating temperatur: -40 ... +85 °C
Fixed PWM ratio (parameterizable) or PWM ratio depending on the operating voltage
PWM frequency: 20 KHz (acoustically inaudible)
Rating: 4A continuous
Peak current: 70 A briefly (starting currents)
Microcontroller for customer-specific applications (soft start, overvoltage shutdown, power monitoring)
Dimensions (L x W x H): 50 x 50 x 21 mm
|
|
|  |
 |
|
Ignition spark generator Thermo E+
| ID 1081
For heating system
order development
Compatible ignition spark generator for control Thermo E+
Operating temperatur: -40 ... +85 °C
Operating voltage: 12- and 24 V (2 versions)
Extremely compact design
Optimized assembly concept with only one screw
Dimensions (L x W x H): 44 x 39 x 72 mm
|
|  |
 |
Ignition spark module Thermo G
| ID 1090 For heating system
order development
Compatible ignition spark module for control unit Thermo G
Operating temperatur: -40 ... +85 °C
Integrated ionization monitoring
Dimensions (L x W x H): 65 x 40 x 133 mm
|
|
|  |
 |
|
Ignition spark generator Pro
| ID 1038
For heating system
Ownership: Exotronic
Integrated circuit
Operating voltage: 24 V
Operating temperatur: -40 ... +95 °C
Temperature dependent ignition energy
Cost-optimized replacement electrodes
Dimensions (L x W x H): 74 x 31 x 103 mm
|
|  |
 |
Wireless Diagnostics
| ID 9455
Diagnostic adapter
Ownership: Exotronic
For CAN and S-Bus compatible devices
Bluetooth transmission to smartphone or tablet
No PC required
reading out the diagnosis
Component testing
Dimensions (L x W x H): 104 x 54 x 17 mm
|
|
|  |
 |
|
Diagnostic adapter DTT
| ID 1067
order development
For S-Bus compatible devices
reading out the diagnosis
DTT-Software for PC
Component testing
Dimensions (L x W x H): 159 x 60 x 20 mm
|
|  |
 |
Rain sensor
| ID 1014
order development
Operating voltage: 24 V
Operating temperatur: -40 ... +85 °C
Closes the roof hatches of buses when it rains
Rain monitoring function only active if at least one roof hatch is open
Integrated heater to detect dew
Dimensions (L x W x H): 66 x 55 x 26 mm
|
|
|
 |
2023 © Exotronic GmbH
Data protection
Imprint
|

|
Climate control panel for OEM
ID 1500
• order development
• developed on the basis of a design template
• for DIN mounting frame slot
• customized fully graphic LCD
• 11 buttons and 2 rotary knobs
• Night illumination in amber color
• Dimensions (L x W x H): 187 x 58 x 55 mm
|
Hatch Control Control panel for up to 4 roof hatches
ID 9411
• Ownership: Exotronic
• Compatible with DHC and ELEON control unit
• Operating temperatur: -40 ... +85 °C
• Fully digital with memory function
• Status display of each roof hatch
• Night illumination
• Dimensions (L x W x H): 87 x 61 x 37 mm
|
SC Preheat
Pre-selection timer for heaters
ID 1094
• serial production
• 7 day pre-selection timer
• Illuminated flat membrane keyboard
• Power failure bypass 72 hours
• 12 h / 24 h mode
• Protection class IP54 (front)
• Operating voltage: 12- and 24 V
• Dimensions (L x W x H): 89 x 42 x 41 mm
|
High-voltage control unit for PTC heater
ID 1005
• order development
• Control of 2 PTC heaters with up to 1,200 V
• IP 67 in a CNC milled and sealed aluminum housing
• internal security concept
• CAN- and S-Bus compatible
• Dimensions (L x W x H): 190 x 135 x 56 mm
|
Control unit for roof hatch ELEON
ID 1003
• order development
• Control of 4 motors (always two sequentially)
• Operating temperatur: -40 ... +85 °C
• Operating voltage: 12- and 24 V (2 versions)
• CAN- and S-Bus protocol
• extremely compact and powerful assembly
• Mounting without screws (clip)
• Dimensions (L x W x H): 85 x 56 x 24 mm
|
Control unit Thermo E For heating system
ID 1071
• order development
• Operating voltage: 24 V
• Operating temperatur: -40 ... +85 °C
• Integrated flame detection
• for price-critical markets
• Dimensions (L x W x H): 114 x 101 x 55 mm
|
Control unit Thermo E+ For heating system
ID 1080
• order development
• diagnostic ability with DTT
• Operating voltage: 12- and 24 V (2 versions)
• Operating temperatur: -40 ... +85 °C
• extremely compact and powerful assembly
• integrated circuit for ignition spark generator
• Outside IP 67 Schutz (vacuum potting)
• integrated flame detection
• Dimensions (L x W x H): 112 x 69 x 38 mm
|
Control unit Thermo S For heating system
ID 1018
A control unit, produced by another company for years, had to be converted for our production facility as quickly as possible. In addition to making adjustments to auxiliary devices for our machines, we also had the challenge of redeveloping an end-of-line testing device that was getting on in years. We mastered this conversion process, atypical for us, and have been producing a premium control unit for vehicle heaters at our company since December 2021.
|
Control unit Thermo G For heating system
ID 1089
• order development
• diagnostic ability with DTT
• Operating voltage: 24 V
• Operating temperatur: -40 ... +85 °C
• Integrated ionization monitoring
• integrated circuit for ignition spark generator
• Outside IP 67 Schutz (vacuum potting)
• Dimensions (L x W x H): 108 x 100 x 58 mm
|
Digital Hatch Control (DHC) Control unit for roof hatch
ID 9413
• Ownership: Exotronic
• Compatible with Driver Unit control panel
• diagnostic ability with DTT
• Operating voltage: 24 V
• Operating temperatur: -40 ... +85 °C
• Override closing function (AC)
• Configurable
• Dimensions (L x W x H): 75 x 62 x 20 mm
|
Digital Hatch Control 2 New control unit for roof hatch
ID 9414 Status: In development
• Ownership: Exotronic
• End position detection via motor current monitoring
• Operating voltage: 24 V
• 100% compatible with the DHC
• CAN and S-Bus interface
• Dimensions (L x W x H): 75 x 55 x 17 mm
|
PWM module
ID 9450
• Ownership: Exotronic
• Operating voltage: 9 ... 32 V
• Operating temperatur: -40 ... +85 °C
• Fixed PWM ratio (parameterizable) or PWM ratio depending on the operating voltage
• PWM frequency: 20 KHz (acoustically inaudible)
• Rating: 4A continuous
• Peak current: 70 A briefly (starting currents)
• Microcontroller for customer-specific applications (soft start, overvoltage shutdown, power monitoring)
• Dimensions (L x W x H): 50 x 50 x 21 mm
|
Ignition spark generator Thermo E+ For heating system
ID 1081
• order development
• Compatible ignition spark generator for control Thermo E+
• Operating temperatur: -40 ... +85 °C
• Operating voltage: 12- and 24 V (2 versions)
• Extremely compact design
• Optimized assembly concept with only one screw
• Dimensions (L x W x H): 44 x 39 x 72 mm
|
Ignition spark module Thermo G For heating system
ID 1090
• order development
• Compatible ignition spark module for control unit Thermo G
• Operating temperatur: -40 ... +85 °C
• Integrated ionization monitoring
• Dimensions (L x W x H): 65 x 40 x 133 mm
|
Ignition spark generator Pro For heating system
ID 1038 Status: In development
• Ownership: Exotronic
• Integrated circuit
• Operating voltage: 24 V
• Operating temperatur: -40 ... +95 °C
• Temperature dependent ignition energy
• Cost-optimized replacement electrodes
• Dimensions (L x W x H): 74 x 31 x 103 mm
|
Wireless Diagnostics Diagnosic adapter
ID 9455 Status: In development
• Ownership: Exotronic
• For CAN and S-Bus compatible devices
• Bluetooth transmission to smartphone or tablet
• No PC required
• reading out the diagnosis
• Component testing
• Dimensions (L x W x H): 104 x 54 x 17 mm
|
Diagnostic adapter DTT
ID 1067
• order development
• For S-Bus compatible devices
• reading out the diagnosis
• DTT-Software for PC
• Component testing
• Dimensions (L x W x H): 159 x 60 x 20 mm
|
Rain sensor
ID 1014 Status: obsolete
• order development
• Operating voltage: 24 V
• Operating temperatur: -40 ... +85 °C
• Closes the roof hatches of buses when it rains
• Rain monitoring function only active if at least one roof hatch is open
• Integrated heater to detect dew
• Dimensions (L x W x H): 66 x 55 x 26 mm
|
2023 © Exotronic GmbH
Data protection
Imprint
|